Any steel players who are also Plumbers?
Moderator: Shoshanah Marohn
Any steel players who are also Plumbers?
I've got a very weird plumbing problem at home. A week ago we had a new clothes washer installed. That just involves hooking up two hoses and plugging the durn thing in. Done.
Then we noticed that upstairs in the sink in the master bathroom, the cold water tap ran HOT! The only thing that had changed in our house was the new washer, but I can't imagine how that could be related.
So we did some tests:
1) We turned OFF both the cold and hot taps to the washer and waited about 30 minutes, then tried the upstairs sink again. Result: COLD water!
2) We turned the taps back ON to the washer and tried the upstairs sink again. Result: HOT water!
We have repeated these tests multiple times, always with the same results.
What the heck??
And this is happening without even RUNNING the washer; just having the hot and cold taps turned on. So when the taps are on, I figure there's really just a flexible pipe of stagnant hot water and a flexible pipe of stagnant cold water between the tap and the washer, going nowhere, since the washer isn't turned on and flowing any water.
So how could this possibly HAPPEN?? Both our plumber and our appliance dealer are mystified.
Any ideas out there in steel-guitar-land??
Weird, huh?
Thanks in advance,
Jim
Then we noticed that upstairs in the sink in the master bathroom, the cold water tap ran HOT! The only thing that had changed in our house was the new washer, but I can't imagine how that could be related.
So we did some tests:
1) We turned OFF both the cold and hot taps to the washer and waited about 30 minutes, then tried the upstairs sink again. Result: COLD water!
2) We turned the taps back ON to the washer and tried the upstairs sink again. Result: HOT water!
We have repeated these tests multiple times, always with the same results.
What the heck??
And this is happening without even RUNNING the washer; just having the hot and cold taps turned on. So when the taps are on, I figure there's really just a flexible pipe of stagnant hot water and a flexible pipe of stagnant cold water between the tap and the washer, going nowhere, since the washer isn't turned on and flowing any water.
So how could this possibly HAPPEN?? Both our plumber and our appliance dealer are mystified.
Any ideas out there in steel-guitar-land??
Weird, huh?
Thanks in advance,
Jim
- Bill Moore
- Posts: 2099
- Joined: 5 Jun 2000 12:01 am
- Location: Manchester, Michigan
Jim, I'm not a plumber, but I was a pipefitter for many years. I would check to see if the hoses connected to the washer are connected to the correct inlets on the washer. Maybe even switch the hoses and see what happens. If that doesn't seem wrong, the problem is in the washer itself. There is a "mixing valve" built it to it somewhere. That allows you to mix the hot and cold, say if you want to use "warm" water for the wash. These mixing valves are designed to not allow either the hot or cold water to "backflow" into the other side. If you continue to have a problem, I would contact the manufacturer of the washer, and see what they say. If they can't help, you should have the washer exchanged for a different one.
- Randy Beavers
- Posts: 1291
- Joined: 4 Nov 1998 1:01 am
- Location: Lebanon,TN 37090
- Contact:
Well the washer is still under full warranty, of course, and the appliance folks are going to order a new set of valves for it and replace the valves (which would include that cross-valve you mentioned), so we'll see if that works. We did, of course, check that the hoses are connected to the right sides of the washer and they were. Thanks, Bill.Bill Moore wrote:I would check to see if the hoses connected to the washer are connected to the correct inlets on the washer. Maybe even switch the hoses and see what happens. If that doesn't seem wrong, the problem is in the washer itself. There is a "mixing valve" built it to it somewhere. That allows you to mix the hot and cold, say if you want to use "warm" water for the wash. These mixing valves are designed to not allow either the hot or cold water to "backflow" into the other side. If you continue to have a problem, I would contact the manufacturer of the washer, and see what they say.
Randy: That's just "plumb wrong" but thanks for illustrating what ya get when you ask a plumbing question to a steel player... On the other hand, if I ever have a drywall question, I'll know where to go!
Last edited by Jim Cohen on 16 Jul 2013 9:52 am, edited 1 time in total.
- Shorty Rogers
- Posts: 206
- Joined: 9 Dec 2008 9:48 am
Jim, I think Bill is on the right track. Me thinks the the mixing valve may well be involved, assuming the hoses are properly hooked up. Try setting the wash/rinse temp on the washer to cold/cold. Turn the washer on so that the solenoids that operate the intake valves have a chance to power up and move in the event that one is stuck. Turn the washer off and test the bath sink water temp. Next try the same thing with the washer temp set to hot. Depending on what may change, you might get a better sense of what is going on. Another thing to check is if your house has a recirculating pump for the hot water. These pumps push hot water through a loop that allows for instant hot water at taps some distance from the water heater, like upstairs. It is possible that between a circulating pump and the mixing valve, your bath sink is pulling a mix of hot and cold, which would really be more of a warm water than hot.
Actually, I thought that they locked up the Plummers after Watergate. Good luck.
Actually, I thought that they locked up the Plummers after Watergate. Good luck.
Well, let me put my "qualifications" this way: My son is much more of a plumber than I am a steel player.
I think shorty and others are on to it. The mixing valve has to be providing a flow path between hot and cold lines. You can test this by disconnecting one hose... say the cold hose. Then slightly open the other (hot) supply valve and see if there is water escaping the open port of the mixing valve. If not, you should reverse the procedure to see if there is flow the other way, but it appears that hot is bleeding into cold water line.
I think shorty and others are on to it. The mixing valve has to be providing a flow path between hot and cold lines. You can test this by disconnecting one hose... say the cold hose. Then slightly open the other (hot) supply valve and see if there is water escaping the open port of the mixing valve. If not, you should reverse the procedure to see if there is flow the other way, but it appears that hot is bleeding into cold water line.
HagFan
Emmons Lashley LeGrande II
Emmons Lashley LeGrande II
- Bud Angelotti
- Posts: 1363
- Joined: 6 Oct 1999 12:01 am
- Location: Larryville, NJ, USA
- Contact:
Jim - Maybe this will help.
http://www.youtube.com/watch?v=CsKFhOw-PXw
http://www.youtube.com/watch?v=CsKFhOw-PXw
Just 'cause I look stupid, don't mean I'm not.
-
- Posts: 21192
- Joined: 16 Feb 1999 1:01 am
- Location: Glen Burnie, Md. U.S.A.
I see a lot of you suspect the mixing valve, which makes some sense to me until I recall that the washer is not running. So why would just turning on the taps connected to the washer - without the washer running - lead to anything concerning the mixing valve? There is no water flowing through the machine when it's off, is there?
- Bud Angelotti
- Posts: 1363
- Joined: 6 Oct 1999 12:01 am
- Location: Larryville, NJ, USA
- Contact:
Serious this time Jim.
Low water pressure. When the cold water goes to the water heater, the hot water has higher pressure, because it's hot. The mixing valve on the washer might be bad, but with low cold water pressure, the mixing valve can't work properly. So, low water pressure prevents the mixing valve from working properly.
Low water pressure. When the cold water goes to the water heater, the hot water has higher pressure, because it's hot. The mixing valve on the washer might be bad, but with low cold water pressure, the mixing valve can't work properly. So, low water pressure prevents the mixing valve from working properly.
Just 'cause I look stupid, don't mean I'm not.
That makes some sense, Bud. but why would the mixing valve need to "work properly" when the dang thing is OFF? Ain't it just sittin' there??
Here's one more piece to the puzzle to contemplate:
The water runs hot for about one minute, then returns to cold. (To me, that seems like it's using up a finite amount of hot water then returning to the regular cold stream.)
Here's one more piece to the puzzle to contemplate:
The water runs hot for about one minute, then returns to cold. (To me, that seems like it's using up a finite amount of hot water then returning to the regular cold stream.)
- Bud Angelotti
- Posts: 1363
- Joined: 6 Oct 1999 12:01 am
- Location: Larryville, NJ, USA
- Contact:
It's not getting enough cold water to mix with the hot because the water pressure is low to the house. Plus the mix valve might be defective.
Find your main water valve where it comes in from the street and check that the MAIN water valve is all the way open.
Find your main water valve where it comes in from the street and check that the MAIN water valve is all the way open.
Just 'cause I look stupid, don't mean I'm not.
- Rick Barnhart
- Posts: 3046
- Joined: 23 May 2008 2:21 pm
- Location: Arizona, USA
-
- Posts: 3296
- Joined: 2 May 2008 3:15 pm
- Location: Columbia, Mo. U.S.A.
The mixing valve that most are referring to is actually a solenoid valve with built in checks inside. My opinion would be that the solenoid valve is bad, which is allowing the hot and cold to mix together even when not in use. Just my opinion. Will be interesting to find out what ends up solving your problem. Larry
Mullen G2 SD10 3 & 5 The Eagle
NV112 amp===Earnie Ball V.P.
NV112 amp===Earnie Ball V.P.
-
- Posts: 115
- Joined: 11 Jun 2007 1:27 pm
- Location: Wyoming, USA
sink
Hey Jim,
Just swap the handles on the sink.
Just swap the handles on the sink.
- Erv Niehaus
- Posts: 26797
- Joined: 10 Aug 2001 12:01 am
- Location: Litchfield, MN, USA
- Bob Hickish
- Posts: 2283
- Joined: 23 Feb 2004 1:01 am
- Location: Port Ludlow, Washington, USA, R.I.P.
- Doug Beaumier
- Posts: 15642
- Joined: 4 Aug 1998 11:00 pm
- Location: Northampton, MA
- Contact:
Jim, I was a union plumber for 30 years. Here's is what you need to do. Buy a 1/2" check valve and put it on the cold side before the cold valve that you hook your washer to. . That washer is not preventing back flow and is overpressuring your cold supply water system creating hot into the cold. This will solve the problem. Turn house water off when you remove the cold valve from the wall by the washer. then install new check valve with "arrow" flow toward washer then put valve back on, hook hose back up. that should solve the problem. they cost about 6.50
-
- Posts: 262
- Joined: 30 Mar 2006 1:01 am
- Location: BastropTexas, USA 78602
plumbing
Check first to see that the piping to the washer box is not crossed. Should be hot on the left cold on the right.