Rectifier Tube question -Fender Tremolux...

Post by Bob Carlucci »

My BF Tremolux started losing power, distorting, and blowing fuses.. It was totally electronically restored by Tracy Sands, and he has an excellent reputation.. Anyway, I pulled the power tubes and rectifier out, powered it up, and it idled for hours, no problem... Put the power tubes back in, still idles for hours no problem.. The rectifier is a Chinese built Rubytubes 5AR4... I have heard that the MIC 5AR4 tubes had a failure rate approaching 50%.. Just something I read online...

So now that is does not blow fuses and all tubes except the rectifier are in and the amp is on, NOT on standby, should I assume it was a bad 5AR4, replace it, and see what happens??... Any other advice???... bob
I'm over the hill and hittin'rocks on the way down!

no gear list for me.. you don't have the time......
User avatar
Michael Hummel
Posts: 467
Joined: 13 Jun 2012 8:53 am
Location: Ottawa, Ontario, Canada

Post by Michael Hummel »

Well, you could try it...but if the rectifier is not in, then you aren't supplying the power tubes with B+ so they aren't really working at all.

Don't be surprised if something else is still wrong, but if the rectum-friers have that bad a reputation, that's what I would try first!

Mike
MSA Classic 5+4
Too many 6-strings and amps to list
Larry Robinson
Posts: 261
Joined: 2 Jul 2003 12:01 am
Location: Peachtree City, Georgia, USA

Post by Larry Robinson »

Easiest check is replace rectifier, then check B+ voltages. If it still blows fuse, a shorted tube, capacitor or OT COULD be problem. Remove all tubes except 5AR4. If it still blows fuse, I suspect a shorted filter cap although it could be something else.
User avatar
Tim Marcus
Posts: 1671
Joined: 9 Nov 2005 1:01 am
Location: San Francisco, CA
Contact:

Post by Tim Marcus »

I always add 2 diodes in series with pin 4 and 6 of the rectifier tube - that way if the tube shorts, the diodes protect the expensive power transformer. You can add a terminal strip to the socket lug and run them right to the socket.

also, if the tube shorts in the middle of you using the amp, the amp will still work (it will get a bit louder and gritty because of higher B+)

if the tube opens up, the amp will die but still have a power light on
User avatar
Tim Marcus
Posts: 1671
Joined: 9 Nov 2005 1:01 am
Location: San Francisco, CA
Contact:

Post by Tim Marcus »

found a picture

I use 6A 1000V diodes

Image
User avatar
Ken Fox
Posts: 9620
Joined: 20 Apr 2001 12:01 am
Location: Nashville GA USA

Post by Ken Fox »

Looks like a 1N4007, 1 amp diode at 1000 PIV. I have 6 amp diodes in the shop, they are a lot bigger around than that.
User avatar
Tim Marcus
Posts: 1671
Joined: 9 Nov 2005 1:01 am
Location: San Francisco, CA
Contact:

Post by Tim Marcus »

good eye! The picture is from one of my low power amps. It is more of a general reference of how to do it.

on the big amps, I use the big guns and yeah, they are a little thicker. The leads on the 6A diodes are really something to contend with!
User avatar
Ken Fox
Posts: 9620
Joined: 20 Apr 2001 12:01 am
Location: Nashville GA USA

Post by Ken Fox »

That is a good idea, Tim. I have seen it before on a website for recommended mods for tube amps.

Yea, those 6 amp diodes are some honkers for sure. I like to also use a CL-60 (current limiting thermistor) in series with the hot side to the AC fuse to help slow in-rush current. I did that on the amps I was building. I also fused the 5 VAC and 6.3 VAC supplies as well.
Bob Carlucci
Posts: 6965
Joined: 26 Dec 2003 1:01 am
Location: Candor, New York, USA

Post by Bob Carlucci »

well anyway, Put all tubes back in, ran it for hours and hours.. Been playing it on and off last 2 days.. No issues.. Who knows????.... bob
I'm over the hill and hittin'rocks on the way down!

no gear list for me.. you don't have the time......
User avatar
Jerry Kippola
Posts: 241
Joined: 11 Jun 2011 8:12 am
Location: UP Michigan, USA

Post by Jerry Kippola »

check the rec tube pins, I've seen many where the solder breaks in the pin, and just resolder it
.
User avatar
Tony Prior
Posts: 14522
Joined: 17 Oct 2001 12:01 am
Location: Charlotte NC
Contact:

Post by Tony Prior »

When I first acquired my 64 Tremolux, it blew fuses as well , it was indeed caps on the RECT side of the stand by switch...16 ufd's...the rectifier socket was also suspect but not the problem, the caps were. The good news was that the caps did not take out the GZ34.


In this case I would revisit the rect tube and socket.

I would let it sit with the Rect tube installed and the power tubes OUT...the reverse of what you did...monitor the B+

or not !

I really like Tim's photo above, great recommendation....
Emmons L-II , Fender Telecasters, B-Benders
Pro Tools 8 and Pro Tools 12
jobless- but not homeless- now retired 8 years

CURRENT MUSIC TRACKS AT > https://tprior2241.wixsite.com/website
User avatar
Ken Fox
Posts: 9620
Joined: 20 Apr 2001 12:01 am
Location: Nashville GA USA

Post by Ken Fox »

I agree, Tony. I would monitor the temp on those 16uf caps. If they have a high ESR, they will be getting warm. If so, replace them. Also if the bias was set too hot then the amp may be going into "red-plating) on the power tubes. Looks for red spots on the plates of the power tubes. If you see them it is biased too hot and can go into full red-plating, which will blow a fuse quickly.
Bob Carlucci
Posts: 6965
Joined: 26 Dec 2003 1:01 am
Location: Candor, New York, USA

Post by Bob Carlucci »

Never red plated.. Tubes NEVER ran hot... At this point, it no longer blows fuses, and I have no idea why it did in the first place.. I did run run the amp with no power tubes and rectifier in for hours, and power tubes in rectifier out for hours,, never once at any time I have had this amp did the power tubes get anywhere near hot.. Its been days.. i play it every day, and its been fine... I have no idea what happened... bob
I'm over the hill and hittin'rocks on the way down!

no gear list for me.. you don't have the time......
User avatar
Tony Prior
Posts: 14522
Joined: 17 Oct 2001 12:01 am
Location: Charlotte NC
Contact:

Post by Tony Prior »

Bob , the amp is broken and cannot be repaired, please send it to me I will dispose of it for you ! :)
Emmons L-II , Fender Telecasters, B-Benders
Pro Tools 8 and Pro Tools 12
jobless- but not homeless- now retired 8 years

CURRENT MUSIC TRACKS AT > https://tprior2241.wixsite.com/website
User avatar
Stephen Cowell
Posts: 2875
Joined: 6 Jan 2012 8:13 am
Location: Round Rock, Texas, USA

Post by Stephen Cowell »

Are you using slo-blo fuses? Heating up the filter caps may have re-formed them... Or you might have a carbon trail across some tube pins that you disturbed when you pulled the tubes (doubtful). If this is a gigging amp I'd have it thoroughly gone over.
New FB Page: Lap Steel Licks And Stuff: https://www.facebook.com/groups/195394851800329