reverb problem on nash 400
Moderator: Shoshanah Marohn
-
- Posts: 71
- Joined: 26 Feb 2000 1:01 am
reverb problem on nash 400
Hi everybody,I've put a hand on a old Nashville 400(around 89)and after two minute of operation the reverb fall down,I close the amp some minute and when I put it on, the reverb is back again for two or three minute and fall down again,big problem or just a little visit at the Peavy doctor?someone know about this?thank you and have a great new year,sylvain
- Jerry Heath
- Posts: 92
- Joined: 3 Jan 2005 1:01 am
- Location: Harrah, Oklahoma, USA
- Contact:
I'd check the molex connector. Make sure it's not loose. This is a common problem. Do a search on the forum for "molex" you'll see other people having the same problem and you'll also find some recommended fixes.
Jerry Heath
Sierra Sessions U-12
MSA Vintage XL U-12
Nashville 400
Sessions 400
Profex II
Pod XT
Hilton Volume Pedal
Sierra Sessions U-12
MSA Vintage XL U-12
Nashville 400
Sessions 400
Profex II
Pod XT
Hilton Volume Pedal
- Jack Stoner
- Posts: 22087
- Joined: 3 Dec 1999 1:01 am
- Location: Kansas City, MO
The connector that plugs into the underside of the amp from the reverb pan (a "Molex" brand connector) is the weak spot in the reverb system. Sometimes just "reseating" the connector (taking it off then plugging back in) will "clean the contacts". Other times taking the connector off then spraying contact cleaner on both the male and female pins will fix it. Other times one of the female pins in the connector will need "reforming" (making smaller) so it makes good mechanical/electrical contact.
There can be other problems but the majority of times the connector is the culprit.
There can be other problems but the majority of times the connector is the culprit.
-
- Posts: 71
- Joined: 26 Feb 2000 1:01 am
-
- Posts: 5857
- Joined: 4 Aug 1998 11:00 pm
- Location: Oceanside, Calif, USA
- Contact:
If you continue to have problems- remove the chassis from the cabinet (remove the back plate from the cabinet, the 4 screws on top, the speaker and reverb connections, and the power cord hold down inside the cabinet) and check the solder joints on the other side of the molex connector. Just another common area of concern on those amps.
-
- Posts: 5027
- Joined: 4 Aug 1998 11:00 pm
- Location: Meridian, Mississippi USA
N 400
Ensure that the two bare wires of the reverb harness are not touching each other.
-
- Posts: 71
- Joined: 26 Feb 2000 1:01 am
-
- Posts: 5027
- Joined: 4 Aug 1998 11:00 pm
- Location: Meridian, Mississippi USA
Problem?
What did you find that was causing the problem? Just curious.
-
- Posts: 71
- Joined: 26 Feb 2000 1:01 am